This page has relevant information about NIA examination past questions and answers. Here, we provide up to date compilations of NIA professional practice examination past questions and answers. You can download NIA PPE past questions and answers on this page to enhance your studies and preparation. Nigerian Institute of Architects past questions 2021.

NIA Examination Past Questions

The following are samples of free NIA past questions.

1. A foundation is being built in clay soil. If the area of a correctly designed footing has an area of 12 square feet and the applied load is 24,000 pounds, then what is the bearing capacity of this soil?
a) 500 pounds per square foot
b) 2000 pounds per square foot
c) 288 kips per square foot
d) 2 kips per square foot

2. What advantage is gained by adding calcium chloride to concrete as an admixture?
a) It accelerates the hydration rate.
b) It allows a lower water-cement ratio in the concrete.
c) It decreases the likelihood of corrosion of reinforcing steel in the future.
d) It increases the final strength of the concrete after it has cured fully.

3. A slump test is performed on concrete used in a building slab. The concrete slumps one inch during the test. What conclusions can be drawn about the concrete that this sample is from?
a) This concrete is rigid and may not be very workable.
b) This concrete slumps within the tolerable range and should have good stiffness and workability.
c) This concrete is not rigid enough and may be too soft to be properly workable.
d) The slump test is no longer used to gauge the stiffness and workability of concrete.

4. Where should the vapor barrier be placed in the wall construction in a cooling climate such as Phoenix, Arizona?
a) On the exterior side of the thermal envelope
b) On the interior side of the thermal envelope
c) A vapor barrier is not needed
d) On both the interior and exterior side of the thermal envelope

5. Which of the following is a disadvantage of pursuing a design/bid/build method of project delivery?
a) A firm price is not known until the construction documents are mostly completed.
b) Competitive bidding typically will result in a lower cost than if a contractor is selected earlier in the design process
c) The contractor will not be present to act in the best interest of the owner during design.
d) There is a risk that design changes will cause significant issues because construction begins before the documents are finished.

6. Why is an additive alternate to a bid preferable to a deductive alternate to a bid?
a) Because the contractor will usually deduct less than the actual value of the work installed when putting together a deductive alternate.
b) Because a bid with additive alternates has a lower base price.
c) Because the bid can be put together in less time if additive alternates are used.
d) Because it is easier for the subcontractors to price additive alternates.

7. Which of the following materials has the highest shading coefficient (SC)?
a) One-eighth of an inch of clear glass
b) Half-inch clear glass
c) Quarter-inch heat absorbing glass
d) One-inch insulated glass

8. Which of the following is NOT a characteristic of a ramp that is handicapped accessible?
a) It has a minimum five-foot-long landing ramp at the top and the bottom.
b) It has a maximum length of 30 feet.
c) It has a maximum rise of 24 inches before a landing is required.
d) It has a minimum width of 36 inches.

9. Which of the following is NOT a principle that Clarence Perry championed in his “Neighborhood Theory” in 1929?
a) Arterial streets should form the boundaries of each neighborhood, but should not pass through them at all.
b) The population of the neighborhood should not be greater than can be accommodated by one elementary school.
c) Shopping areas should be located along the arterials around the edges of the neighborhood.
d) The streets inside the neighborhood should be laid out in a grid, with many connections to arterials.

10. The footprint of a building is 10,000 square feet, has eight stories, and the site is 100,000 square feet. What is the FAR for the site in this instance?
a) 0.1
b) 0.8
c) 1.25
d) 10

11. What is the definition of an arterial road?
a) A road with on/off ramps and speed limits that are usually 55 miles per hour or higher.
b) A road that runs through the residential area of a neighborhood.
c) A road that residential streets connect to in order to take traffic to a main thoroughfare.
d) A high capacity road that connects to freeways.

12. Which of the following is NOT usually true when describing the cross section of a street?
a) If there is a sidewalk, it is included in the right of way of the street.
b) The street is sloped so that the high point is in the middle and it drains to the edges.
c) The traffic lanes are typically 9-12 feet in width.
d) Roads are typically sloped one inch per foot or higher to ensure proper drainage.

How to Download NIA Examination Past Questions PDF

We have these past questions available in PDF soft copy. The past questions are offered at the price of 3,000 naira only. The following information is required in order to confirm purchase, and also deliver the past questions and answers to you after paying. Quickly call us now to book/confirm order, or send the following details to us via 08100923529.

  1. Proof of payment (i.e, depositor’s name or screenshot of payment receipt).
  2. Name of past question purchased
  3. A valid email address.

Make payment now to the account details below in order to download the past question papers.

Bank Name: Guarantee Trust Bank

Account Number: 0523296040

Account Name: JAMES MKPONKEABASI CLEMENT

Assurance of Delivery

We know how difficult it is to transact online, considering the high level of scam/ fraudulent activities these days. In a bid to be able convince our customers, we have publish some samples above which you must have while reading about these past questions download. Just as seen on the sample, the complete past questions contains the full question of which the samples were derived from. You can count on us to deliver the past questions to you as the samples proofs the availability of the past questions. Thank you for your understanding. We so much cherish your patronage.

 

NIA Examination Requirements

Professional Practice Examinations (PPE); Finals I (Part I) or Finals II (Part II) Examinations.

NIA PROFESSIONAL PRACTICE EXAMINATIONS 

This examination is open to candidates in the following qualifications:

(a) Associate members of the Institute who have had a minimum of two years supervised post-qualification practice.

(b) Graduate Architects with M.Sc (Arch) or equivalent from .NIA-recognized institutions Overseas with a minimum of two years supervised post-qualification practice (Six months of which must have been spent in Nigeria).

(c) Candidates who are members of corresponding Institutes in-foreign Countries and who have practiced for a minimum of six months in Nigeria. .

(d) Candidates who have passed the NIA Finals II (Part 2) Examination with a minimum of 2 years cognate work experience thereafter.

(e) Candidates in all cases must be currently resident in Nigeria and also fully involved in Architectural practice under the supervision of a financial Full Member of the NIA who has a minimum of three years membership.

(f) Candidates for PPE re-sit papers must submit their application forms.

Requirements & Basic Conditions for ARCON Membership

The following basic qualifications shall be required for the various classes of membership listed below.

 Full Membership:

Full Members shall be holders of an accredited Masters Degree or equivalent qualification in Architecture obtained from any School of Architecture or institution in the Federation or abroad and who shall satisfy all the conditions for admission to Full Membership of the Institute.

Applicants to this class shall satisfy the following conditions:

(I) shall not be less than twenty-one years of age.

(ii) Shall have been an Associate Member

(iii) Must be actively engaged in the practice of Architecture,

(iv) Shall have satisfied all the requirements for Full Membership of the Nigerian Institute of Architects as stipulated in the Bye-Laws.

(v) Shall have had at least two years approved post qualification practical experience after which they must have passed the Professional Practice Competence Examination of the Institute, and shall also fulfill any other condition(s),which may be required by the Executive Council.

Associate Membership:

Applicants to this class shall satisfy the following conditions

(I) Associate Members shall be holders of an accredited Masters Degree or equivalent qualification in Architecture obtained from any School of Architecture or institution in the Federation or abroad and who shall satisfy all the conditions for admission to Associate

(ii) Associate Members shall have been Student and or Graduate Members of the Institute.

Graduate Membership:

Applicants to this class shall satisfy the following conditions:

(I) Graduate Members shall be holders of an accredited Bachelors degree or equivalent qualification in Architecture obtained from any School of Architecture or institution in the Federation or abroad and who shall satisfy all the conditions for admission to Graduate

(II) Graduate Members shall have been Student Members of the Institute, except Graduate applicants from schools outside Nigeria.

Architectural Technologist (HND):

Applicants to this class shall satisfy the following conditions:

(I) Architectural Technologist Members shall be holders of an accredited Higher National Diploma or equivalent qualification in Architecture obtained from any Polytechnic or institution in the Federation or abroad and who shall satisfy all the conditions for admission to Architectural Technologist Class of Membership of the Institute.

(II) Architectural Technologist Members shall have been Student Members of the Institute, except applicants from schools outside Nigeria.

Student Membership:

Applicants to this class shall fulfill the following conditions:

(I) Shall have obtained the minimum entry qualification (s) for the study of Architecture and shall have been enrolled into an accredited University in the Federation or abroad or

(II) Shall have been enrolled in an accredited HND architecture programme of a Polytechnic in the Federation or abroad. Applications forms for these various classes of membership can be obtained from the NIA website https://nia.ng/admission-and-exam/

 

 

One thought on “NIA Examination Past Questions and Answers | Download Latest PDF 2021

Leave a Reply

Your email address will not be published. Required fields are marked *